Recommended insulation R-value by climate zone, and how many inches it takes

Updated: November 2026

ENERGY STAR’s recommended insulation R-value for an existing attic is R-30 in climate zone 1, R-49 in zones 2 and 3, and R-60 in zones 4 through 8. Floors over unheated space range from R-13 in zones 1 and 2 to R-38 in zones 7 and 8 (ENERGY STAR). R-60 works out to roughly 16 to 19 inches of settled loose-fill cellulose, or 22 to 27 inches of loose-fill fiberglass. The tables below give the recommended R-values by climate zone, the code minimums for new homes, and the depth of each common material for R-30 through R-60.

How do I find my insulation climate zone?

Insulation climate zones are assigned county by county and numbered 1 through 8. No recommended R-value on this page falls as the zone number rises. The current reference is PNNL’s Guide to Determining Climate Zone by County, published October 21, 2022. It uses the zone designations in the 2021 IECC and IRC (the model energy code and the model residential building code) and supersedes the 2010 Building America guide, so a zone looked up years ago is worth checking again.

Look up the county by name; the state alone does not settle the zone. Some zones carry a letter after the number. The tables below list Zone 4C, the marine part of Zone 4, separately from 4A and 4B, and Table 3 calls the same area “Marine 4”.

Recommended R-values by climate zone for existing homes

Table 1 is ENERGY STAR’s retrofit guidance for existing wood-framed houses. ENERGY STAR defines R-value as insulation’s ability to resist heat flow, so a higher number means better thermal performance (ENERGY STAR). Use the first attic column for a bare attic floor. Use the second when 3 to 4 inches of insulation already cover it. ENERGY STAR lists both columns under “Add Insulation to Attic” but does not say whether the second column is an amount to add or a total.

Table 1. ENERGY STAR attic and floor targets for existing homes

Climate zone Attic, uninsulated Attic, 3–4 in. already in place Floor
1 R-30 R-25 R-13
2 R-49 R-38 R-13
3 R-49 R-38 R-19
4A, 4B R-60 R-49 R-19
4C, 5, 6 R-60 R-49 R-30
7, 8 R-60 R-49 R-38

Source: ENERGY STAR, Recommended Home Insulation R-Values, viewed November 23, 2026.

The floor column covers insulation installed on the underside of a floor, usually one above a crawlspace or an unheated basement. A floor over a crawlspace in Zone 5, for example, has a target of R-30.

What R-value do walls and basement walls need?

ENERGY STAR’s wall guidance is written for the point when exterior siding comes off. For an uninsulated wood-frame wall, the sequence is to blow insulation into the empty cavities and then add insulative sheathing (rigid insulation board installed under the new siding). A 2×4 wall that already has cavity insulation gets the sheathing only (ENERGY STAR).

Wood-frame house wall with the siding removed and rigid insulation boards fastened over the sheathing

Basement and crawlspace walls have two options in each zone: a thinner layer of insulative sheathing, or a batt with a higher rating.

Table 2. ENERGY STAR wall and basement wall targets for existing homes

Climate zone Uninsulated wall: fill cavity, then add sheathing Insulated 2×4 wall: add sheathing Basement or crawlspace wall
3 R-5 Not listed R-5 sheathing or R-13 batt
4A, 4B R-5 to R-10 R-10 R-10 sheathing or R-13 batt
4C R-5 to R-10 R-10 R-15 sheathing or R-19 batt
5–8 R-5 to R-10 R-10 R-15 sheathing or R-19 batt

Source: ENERGY STAR, Recommended Home Insulation R-Values, viewed November 23, 2026. The ENERGY STAR wall and basement figures summarized here cover Zones 3 through 8, so Zones 1 and 2 do not appear.

What does the building code require for new homes?

Code minimums for ceilings in new homes have gone up in every zone except Zone 1 since 2009. Table 3 shows the ceiling R-values required under three editions of the IECC, as compiled by PNNL’s Building America Solution Center (BASC).

Table 3. IECC minimum ceiling R-values for new homes

Climate zone 2009 IECC 2012–2018 IECC 2021 IECC
1 R-30 R-30 R-30
2 R-30 R-38 R-49
3 R-30 R-38 R-49
4 (except Marine) R-38 R-49 R-60
5 and Marine 4 R-38 R-49 R-60
6 R-49 R-49 R-60
7, 8 R-49 R-49 R-60

Source: BASC (PNNL), 2009–2021 IECC and IRC Minimum Insulation Requirements for New Homes, last updated September 17, 2021.

The 2021 column matches the uninsulated-attic column of Table 1, zone for zone. The match is by design: ENERGY STAR bases its retrofit table on Chapter 4, Table R402.1.3 of the 2021 IECC Residential Provisions (ENERGY STAR). The code that governs a particular house is the edition its state or city has adopted, and that may be older than 2021. The local building department can say which one applies. Code wall minimums are not reproduced here.

R-value per inch by insulation type

Table 4 lists typical R-values per inch from PNNL and DOE. Where a range is given, actual products fall somewhere inside it.

Table 4. Typical R-value per inch, air barrier status and vapor retarder class

Material R-value per inch (ft²·h·°F/Btu per in.) Air barrier Typical vapor retarder class
Fiberglass batt or board 2.5–4 No Not listed
Mineral wool rigid board 3–4 No Not listed
Expanded polystyrene (EPS) 3.8–4.4 Yes Class III
Extruded polystyrene (XPS) 5 Yes Class II
Polyisocyanurate About 6 Yes Class I, depending on facing
High-density polyurethane spray foam About 6 Yes Class II
Loose-fill cellulose, settled 3.2–3.8 Not listed Not listed
Loose-fill fiberglass, settled 2.2–2.7 Not listed Not listed

Sources: first six rows from BASC (PNNL/DOE), Typical R-values and Vapor Retarder Classifications, last updated December 23, 2021. Loose-fill rows from the BASC Loose-Fill Insulation tool, which cites DOE’s “Loose-Fill Insulations” (May 1995), at a settled density of 1.5–2.0 lb/ft³ for cellulose and 0.5–1.0 lb/ft³ for fiberglass.

The vapor retarder class describes how much water vapor a material lets through, measured in perms. Class I is 0.1 perm or less, Class II is above 0.1 and below 1.0, and Class III is above 1.0 and below 10 (BASC). A lower class number means less vapor gets through.

How many inches of insulation is R-38, R-49 or R-60?

The depth for a target R-value is the target divided by the material’s R-value per inch. Table 5 runs that division at both ends of each range in Table 4, so the smaller number in each cell is the depth for a product at the top of the range and the larger number is for one at the bottom.

Close-up of white loose-fill fiberglass insulation between attic joists with a wooden dowel standing in it to gauge depth

Assumptions behind Table 5:

  • Loose-fill figures use settled R-value per inch, so the result is the depth after settling.
  • Cellulose settles 10 to 20 percent over time; fiberglass and rock wool settle 2 to 4 percent (BASC Loose-Fill tool). The blown-depth column for cellulose divides the settled depth by 0.90 at the low end and by 0.80 at the high end.
  • Spray foam uses a single value of R-6 per inch.
  • Results are rounded to the nearest 0.1 inch.

Table 5. Inches of insulation needed for each target R-value

Target Loose-fill cellulose, settled (in.) Cellulose as blown, before settling (in., est.) Loose-fill fiberglass, settled (in.) Fiberglass batt (in.) High-density spray foam (in.)
R-30 7.9–9.4 8.8–11.7 11.1–13.6 7.5–12.0 5.0
R-38 10.0–11.9 11.1–14.8 14.1–17.3 9.5–15.2 6.3
R-49 12.9–15.3 14.3–19.1 18.1–22.3 12.3–19.6 8.2
R-60 15.8–18.8 17.5–23.4 22.2–27.3 15.0–24.0 10.0

Worked example for R-60 in cellulose: 60 ÷ 3.8 = 15.79 inches and 60 ÷ 3.2 = 18.75 inches settled. Before settling, 15.79 ÷ 0.90 = 17.5 inches and 18.75 ÷ 0.80 = 23.4 inches. The same arithmetic for R-60 in loose-fill fiberglass gives 60 ÷ 2.7 = 22.2 inches and 60 ÷ 2.2 = 27.3 inches. Fiberglass settles less, so its allowance is small: even at 4 percent, 27.3 ÷ 0.96 = 28.4 inches, about an inch more.

The R-38 row can be checked against PNNL’s own figures. PNNL recommends 10 to 12 inches of cellulose and 14 to 17 inches of fiberglass for R-38 (BASC Loose-Fill tool), which matches the 10.0–11.9 and 14.1–17.3 inches calculated here.

Table 5 is a way to check whether a quote or a bag count is in the right range. It does not replace the coverage chart for a specific product. PNNL states that loose-fill “should always be installed at the manufacturer’s recommended densities,” and the manufacturer’s chart for that product sets the installed and settled depth.

How do I estimate the R-value of insulation I already have?

The R-value of existing insulation is its depth multiplied by the R-value per inch of the material. For 4 inches of loose-fill fiberglass, that is 4 × 2.2 = R-8.8 at the low end and 4 × 2.7 = R-10.8 at the high end. Reaching R-60 means adding 60 − 10.8 = R-49.2 to 60 − 8.8 = R-51.2, or about R-49 to R-51.

That result is close to Table 1, where ENERGY STAR gives R-49 for Zones 4 through 8 when 3 to 4 inches are already in place. In loose-fill cellulose, the added layer works out to 49.2 ÷ 3.8 = 12.9 inches to 51.2 ÷ 3.2 = 16.0 inches, settled.

  1. Look up the county’s climate zone in the PNNL guide.
  2. Measure the depth of the existing insulation at several points across the attic floor and use a typical value, not the deepest spot.
  3. Identify the material from an old invoice, a leftover bag or the installer’s records.
  4. Multiply the depth by both ends of the material’s range in Table 4.
  5. Subtract the result from the Table 1 target for the zone.
  6. Divide the shortfall by the R-value per inch of the material to be added. That gives the depth to add.

Why insulate before buying a heat pump or solar?

Heating is the largest single energy use in American homes. According to the EIA’s 2020 Residential Energy Consumption Survey, “Heating homes accounted for 42% of energy consumption in the residential sector,” and “Space heating in U.S. households cost $519 on average.” Air conditioning accounted for 9% of total site energy. Attic and floor insulation work on the heating load, and attic insulation also cuts summer heat gain.

ENERGY STAR says sealing and insulating can “provide up to a 10% savings on your annual energy bills” (ENERGY STAR, Seal and Insulate). That is an upper figure, not a prediction for a particular house, and the result depends on the starting point. An attic going from bare to R-60 has more to gain than one going from R-38 to R-49.

A heat pump is sized to the house’s heating load, and a solar array is sized to the electricity the house uses. Both needs get smaller once the attic, floors and walls meet their targets, so measuring and topping up insulation is the step to take before getting quotes. The site’s page on green energy for homes covers solar after the load has been reduced. Other ways to cut use are on the energy savings tips page.

Is there still a tax credit for insulation?

No, not for insulation installed in 2026. The federal Energy Efficient Home Improvement Credit (25C) covered 30 percent of qualified expenses, up to $1,200 a year, for “qualifying property placed in service on or after Jan. 1, 2023, and before December 31, 2025” (IRS, page last reviewed April 28, 2026). Insulation and air sealing materials qualified if they met IECC standards. Installation labor did not.

Work done in 2026 falls outside that window. The home efficiency loans page describes financing routes for an attic upgrade. If a state or utility rebate seems to apply, confirm it with the program before the work starts, because availability differs from place to place.

Frequently asked questions

Is more insulation always better?

More insulation always lets less heat through, but each added inch does less than the one before. Heat flow through an insulation layer is proportional to 1 ÷ R. Going from about R-10 (the 4-inch fiberglass example above) to R-60 cuts heat flow through that layer by 1 − 10/60 = 83 percent. The last step on its own, from R-49 to R-60, cuts it by 1 − 49/60 = 18 percent. These figures assume the same indoor-outdoor temperature difference and count only conduction through the insulation, not framing or air leaks.

Is the ENERGY STAR recommendation the same as the building code?

No. The numbers agree with the 2021 code, but the two do different jobs. ENERGY STAR’s figures are recommendations for existing homes, based on Table R402.1.3 of the 2021 IECC. Code minimums are requirements for new homes, and they follow whichever edition the jurisdiction has adopted. Table 3 shows that under the 2009 IECC, ceiling minimums ranged from R-30 to R-49.

Does air sealing come first?

Air sealing belongs in the same plan as the insulation. Fiberglass batts and boards are not air barriers (BASC), so air leaking through gaps in the ceiling passes straight through them. Once loose fill is down, those gaps are harder to reach. ENERGY STAR lists sealing leaks and adding attic insulation together among its “bigger jobs” (ENERGY STAR).

Do I need a vapor retarder?

The locally adopted code decides, based on the climate zone and the wall, floor or ceiling assembly. Confirm the requirement with the local building department before closing up a wall or ceiling. Some insulation already counts as a vapor retarder: polyisocyanurate is typically Class I depending on its facing, XPS and high-density spray foam are typically Class II, and EPS is typically Class III (Table 4).

Next step: Find the county’s climate zone, measure the existing attic depth, and work out the shortfall against Table 1 before sizing a heat pump or solar system.